If you are using the ab controllogix platform and want a bit to cycle on and off at a consistent rate you can address one of the bits of the register that represents the clock microseconds.
Using the wall clock time in controllogix.
Yet another section would display the total number of seconds that have passed since jan 1 1970.
Furthermore the controllogix processor will not automatically adjust for daylight savings time.
This is where the clock update tool can come in handy.
Needed something like this to transfer system time to an rsview register for an event time stamp.
12 thoughts on reading the controllogix system time in ladder logic steve august 18 2010 at 10 43 pm.
Look at the date time tab in the controller properties window.
Tight integration between the programming software controller and i o modules reduces development time and cost at commissioning and during normal operation.
These sections would be the attributes.
We set the clock forward one hour in the spring and back one hour in the fall.
The controllogix backplane for coordinated system time cst and.
However many programmers began to enable the tz and dst settings inadvertently when using the set time button in controller properties.
For more information.
One section would display the current time in our own time zone.
Time synchronization is accomplished by using these methods standards and protocols.
Still struggling with defining the tag values and getting the proper response.
The scan time of the plc will dictate how fast the register.
Gsv wallclocktime the register containing the microseconds is the 7th element in the array.
Once all the clocks in a control system share a synchronized common understanding of system time events being monitored in the control system for example the controllogix system can be time stamped to a very high degree of accuracy.
Controllogix control systems our controllogix control systems use a common control engine with a common development environment to provide high performance in an easy to use environment.
Another section attribute would be for utc.
All clocks ultimately derive their time from a clock known as the grandmaster clock.
In v16 and later this button not only sets the controller s clock to match the pc s date and time but also sets the controller s clock to match the pc s tz and dst settings.
Unlike the plc 5 slc 500 and micrologix all of which have a status file to access similar information in a controllogix or compactlogix requires a gsv get system variable or ssv set system variable instruction.